Name of the assembly group: X11-CANbus-ELGO
Use function: It serves as an interface for connecting the ELGO-LIMAX Safe CP33 and two CANbus connections.
Time of use: From 2019-02 to 2020-04
Dimensions (with shell): (length x width x height) 36 mm x 77.2 mm x 50 mm
Weight: Approx. 700 gram
Power supply: Terminals 200       -   24V DC
Terminals 500       -     0V GND
Protection level: IP 43 / pollution degree II
Place of installation: In the inspection box
Ambient temperature: 0 to +65 °C

Car - X11-CANbus-ELGO - Module for connecting the ELGO-LIMAXSafe shaft copying system

The new X11-CANbus-ELGO module is the interface board for connecting the SIL-3 SAFE shaft copy in the inspection box. Additionally

A2-56-Interfaces-Steuerschrank.png