TV60-101
| Name of the assembly group: | TV60-101 |
|---|---|
| Use function: | It is used to monitor the door release contacts on elevators with a shortened shaft head &/ shortened shaft pit with KW controls. |
| Time of use: | From 2005-04 to 2007-11 |
| Relay elements: | K139, K140 |
| Dimensions (with shell): | (length x width x height) 56 mm x 77.2 mm x 60 mm |
| Weight: | Approx. 700 gram |
| Power supply: | +24V DC / 230V AC |
| Switching cycles: | Approx. 1,000,000 switching cycles |
| Protection level: | IP 43 / pollution degree II |
| Place of installation: | In the control cabinet |
| Ambient temperature: | 0 to +45 °C |