Return bulb standard RB-2005
| Name of the assembly group: | Return controls |
|---|---|
| Use function: | The return controls are available in three versions: 1.) Return position switch for MRL systems and hydraulic systems 2.) Return bulb for rope elevator systems 3.) Return bulb for the touchdown device for elevator systems with touchdown device |
| Time of use: | From 2005 |
| Relay elements: | None |
| Weight: | Approx. 3000 gram |
| Power supply: | +24V DC / 230V AC |
| Switching cycles: | None |
| Protection level: | IP 43 / pollution degree II |
| Place of installation: | In the switch cabinet / on the switch cabinet |
| Ambient temperature: | 0 to +65 °C |
| KW-Number: | 1100199 |