Skip to main content

The new processor unit PIC-111 makes the passive matrix displays ANZ22, -32, -33, -52, and -53 active units. The supply voltage of the module is +24V DC. The input characteristics can be set between high active (+24V) and low active (0V).

The cabin position can be set as 1-out-of-N, binary, or gray-coded.

14 inputs are available for flexible assignment. The settings are made via the HPG-60 hand terminal. Each input can be programmed with the cabin position, arrows, or scrolling text.

Floor Display:
32 floors can be selected, and for each floor, two positions can be set (blank - 0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ). The animation of the digits can be adjusted. You can choose whether the floor display is shown directly when changing or "rolls in."

Arrows:
The functions "Arrow Up" and "Arrow Down" are freely assignable. The animation of the arrows can be adjusted. You can choose whether the direction arrow remains fixed on the display or "scrolls."

Scrolling Texts:
The following scrolling texts are freely assignable: "OVERLOAD," "EVACUATION," "FIREMAN'S RIDE," "SPECIAL RIDE," and "OUT OF SERVICE."

Name of the assembly group: PIC-111
Use function: The PIC-111 module expands the matrix displays by providing inputs for parallel 1-out-of-N, binary, and gray code control.
Time of use: From 2008
Dimensions (with shell): 86 x 50 mm
Weight: Approx. 150 gram
Power supply: Terminals 200       -   24V DC
Terminals 500       -     0V GND
Cover case: Made of gray Plexiglas, suitable for front panel thickness of 2mm
Protection level: IP 21 / Pollution degree II
Place of installation: Behind the control panel
Ambient temperature: 0 to +45 °C
Control unit: With the PIC-111 -> Parallel-1-out-of-N, Binary, Gray code
KW-Number: 1001000