GL92-101 Brake unit overexcitation - Brakes > In=3A
Name of the assembly group: | GL92-101 |
---|---|
Use function: | The GL92-101 module is the braking device for overexcited brakes with a high rated current > 3A |
Time of use: | From 2019-09 |
Dimensions (with shell): | (length x width x height) 125 mm x 77.2 mm x 100 mm |
Weight: | Approx. 1200 gram |
Power supply: | +24V DC / 230V AC / 205V DC |
Protection level: | IP 43 / pollution degree II |
Place of installation: | In the control cabinet |
Ambient temperature: | 0 to +45 °C |
KW-Number: | 1100242 |
The GL-92-101 braking unit
This braking device is the big brother of the GL90. It is used for overexcited brake coils. After approx. 1.2 seconds, the output voltage is reduced to the set voltage level.
A voltage level between 50 V and 150 V DC can be set on the coding switch. The device is designed for a maximum continuous current of 8 A, which corresponds to a total coil power of approx. 1600 W.