G3BIS70-101 - Module
Name of the assembly group: | G3BIS70-101 |
---|---|
Use function: | Shaft - G3BIS70-101 - assembly The G3BIS70 assembly allows us to dispense with a complex second BIS70 when using two shaft buses, namely 1 and 3, and use a G3BIS70 instead. The ERG-2018 is used for the new SGS-92 shaft pit station. As this requires a bus connection to the D613 extension bus, the G3BIS70 will be used temporarily until the BIS80 is completed in the STG: |
Time of use: | From 201-08 to 2019-05 (replaced by the BIS80-101 interface board) |
Relay elements: | None |
Dimensions (with shell): | (length x width x height) 42 mm x 77.2 mm x 40 mm |
Weight: | Approx. 300 gram |
Power supply: | Terminals 208 - 24V DC
Terminals 500 - 0V GND |
Switching cycles: | None |
Protection level: | IP 43 / degree of protection II |
Place of installation: | In the control cabinet |
Ambient temperature: | 0 to +65 °C |
KW-Number: | 1100140 |