ER-2014 Floor Controller
The ER-2014 floor controller offers 16 inputs and outputs, of which 6 are freely assignable, two piezo buzzer outputs for call acknowledgment, 8 outputs for controlling display panels, 4 outputs for floor gong speakers, as well as the possibility to connect two bus matrix displays and 1x RJ-12 for TFT graphic displays.
All necessary call inputs, as well as arrow outputs, even for selective door control, are available.
The installation of the floor controller takes place in the shaft cable channel. The blue RJ-45 cable and a power cable serve as the bus connection. The lower 7-pin connector with the call lines 2xA & 2xB is intended for door side 1, the upper connector with 2xC & 2xD for door side 2.
The matrix displays are connected to the two black sockets using the RJ-12 cable.
The yellow-marked RJ-12 socket is for high-quality TFT graphic displays with KW bus connection.
Name of the assembly group: | ER-2014-A |
---|---|
Use function: | The ER-2014-A floor controller provides 16 inputs and outputs, as well as the possibility to connect two bus matrix displays and 1x RJ-12 for TFT graphic displays. All necessary call inputs, as well as arrow outputs, even for selective door control, are available. |
Obsolete component: | ER-2014 |
Time of use: | From 2022 |
Relay elements: | None |
Dimensions (with shell): | (length x width x height) 203 mm x 46 mm x 30 mm |
Weight: | Approx. 300 gram |
Power supply: | Terminals 200 - 24V DC
Terminals 500 - 0V GND |
Switching cycles: | None |
Protection level: | IP 43 / Pollution degree II |
Place of installation: | In the elevator shaft – cable channel |
Ambient temperature: | 0 to +45 °C |