ER-2009 Floor Controller
The ER-2009 floor controller offers 16 inputs and outputs (6 of which are freely assignable), two piezo buzzer outputs for call acknowledgment, 8 outputs for controlling display panels, 4 outputs for floor gong speakers, as well as the connection option for two bus matrix displays and 1x RJ-12 for TFT graphic displays.
All necessary call inputs and arrow outputs, even for selective door controls, are available.
The floor controller is installed in the shaft cable duct. The connection cable for the bus is the blue RJ-45 cable, along with a power cable.
The lower 7-pin connector with the call lines 2xA & 2xB is intended for door side 1, while the upper connector with 2xC & 2xD is for door side 2.
The matrix displays are connected using the RJ-12 cable into the two black sockets.
Name of the assembly group: | ER-2009 |
---|---|
Use function: | The floor controller ER-2009 provides 16 inputs and outputs. All necessary call inputs, as well as arrow outputs, even for selective door control, are available. |
Obsolete component: | ER-2005 |
Time of use: | From 2012-10 to 2015-02 |
Relay elements: | None |
Weight: | Approx. 300 gram |
Power supply: | Terminals 200 - 24V DC
Terminals 500 - 0V GND |
Switching cycles: | None |
Protection level: | IP 43 / Pollution degree II |
Place of installation: | In the elevator shaft - cable duct |
Ambient temperature: | 0 to +45 °C |
KW-Number: | 1100154 (Software of the ER-2009 on the hardware of the ER-2014-A) |