Name of the assembly group: Dinacell load measurement for belt drives
Use function: DMG-LLEC6 load measuring system with belt sensors for 2:1 elevator systems. One belt sensor is required per belt. It is installed in the shaft head or at the belt suspension. The belt sensors are connected to the USB distributor, which in turn is connected to the evaluation electronics.
Time of use: From 2024
Relay elements: 2 pieces
Weight: Approx. 1000 gram
Power supply: 24V AC
Switching cycles: Approx. 1,000,000
Protection level: IP 43 / pollution degree II
Place of installation: In the control cabinet
Ambient temperature: 0 to +45 °C
KW-Number: 1000662