Skip to main content
The fire detectors are connected on the lower level. The +24V DC control voltage is available on the second level
Name of the assembly group: DBF16-101
Use function: The DBF16-101 module replaces the terminal blocks on the X1 strip for terminating the fire detectors of the dynamic fire evacuation system. In principle, the module can be used for all additional inputs.
Time of use: From 2017-08 to 2019-05 (replaced by the additional group ZG16-101)
Relay elements: None
Dimensions (with shell): (length x width x height) 58 mm x 77.2 mm x 50 mm
Weight: Approx. 400 gram
Power supply: Terminals 200       -   24V DC
Terminals 500       -     0V GND
Switching cycles: None
Protection level: IP 43 / pollution degree II
Place of installation: In the control cabinet
Ambient temperature: 0 to +65 °C