Name of the assembly group: DBA90-101
Use function: The DBA90-101 converter converts the information from the cabin bus to the KW Displaybus information, allowing a TFT display to operate in bus mode.
Time of use: From 2014 to 2015
Dimensions (with shell): 77 x 44 mm
Weight: Approx. 150 gram
Power supply: Terminals 200       -   24V DC
Terminals 500       -     0V GND
Cover case: Shell from ER-2013
Protection level: IP 21 / Pollution degree II
Place of installation: Behind the control panel
Ambient temperature: 0 to +45 °C
Control unit: KW-Displaybus
KW-Number: 1001056

Warning!
Before operating on the shaft or cabin bus, the DBA90 must be configured using a PC program.
To do this, both jumpers on the DBA90 must be set first. Then, connect the DBA90 to the PC using an RS232 cable or a USB/RS232 adapter, and run the PC program.