DBA90-101 - Converter DAVID-606 to KW-Display-Bus
Name of the assembly group: | DBA90-101 |
---|---|
Use function: | The DBA90-101 converter converts the information from the cabin bus to the KW Displaybus information, allowing a TFT display to operate in bus mode. |
Time of use: | From 2014 to 2015 |
Dimensions (with shell): | 77 x 44 mm |
Weight: | Approx. 150 gram |
Power supply: | Terminals 200 - 24V DC
Terminals 500 - 0V GND |
Cover case: | Shell from ER-2013 |
Protection level: | IP 21 / Pollution degree II |
Place of installation: | Behind the control panel |
Ambient temperature: | 0 to +45 °C |
Control unit: | KW-Displaybus |
KW-Number: | 1001056 |
Warning!
Before operating on the shaft or cabin bus, the DBA90 must be configured using a PC program.
To do this, both jumpers on the DBA90 must be set first. Then, connect the DBA90 to the PC using an RS232 cable or a USB/RS232 adapter, and run the PC program.