Skip to main content
Name of the assembly group: DB-AT-Box-101
Use function: The DB-AT-Box-101 assembly is located behind the external control panel and is used to connect the external control panel components.
Time of use: From 2026-09
Relay elements: None
Dimensions (with shell): (length x width x height) 130 mm x 46 mm x 30 mm
Weight: Approx. 150 gram
Power supply: Terminals 200       -   24V DC
Terminals 500       -     0V GND
Switching cycles: None
Protection level: IP 43 / Pollution degree II
Place of installation: Rear side of the external panel
Ambient temperature: 0 to +45 °C
KW-Number: 1100653