Name of the assembly group: AT-69-101
Use function: The AT69-101 assembly is located behind the outer panel and is connected to the floor controller or to the EAT70 / 69 via an 8-pin (7-wire cable + grounding wire) external call cable. As an improvement over the AT66-101, Transient Voltage Suppression (TVS) diodes and an X-capacitor have been integrated.
Obsolete component: AT66-101
Time of use: From 2013-10
Relay elements: None
Dimensions (with shell): (length x width x height) 18 mm x 45 mm x 20 mm
Weight: Approx. 200 gram
Power supply: Terminals 200       -   24V DC
Terminals 500       -     0V GND
Switching cycles: None
Protection level: IP 43 / Pollution degree II
Place of installation: Rear side of the outer panel
Ambient temperature: 0 to +65°C
KW-Number: 1100134