Name of the assembly group: ABV2017-101
Use function: It is used to control the descent prevention on the overspeed governor. In addition, the function of holding the descent coil under voltage is in the zone range. This requires the signaling of the two zones 71A and 72A, as well as the two feedback channels Z1 and Z2.
The module now has the option of connecting additional capacitor capacities (for 12V coils) -> ABV2017-XP module.
Obsolete component: ABV2013-102
Time of use: From 2017-08
Relay elements: K10, K71A, K72A, K83, K83A
Dimensions (with shell): (length x width x height) 135 mm x 77.2 mm x 90 mm
Weight: Approx. 900 gram
Power supply: +24V DC / 230V AC
Switching cycles: Approx. 1,000,000 switching cycles
Protection level: IP 43 / pollution degree II
Place of installation: In the control cabinet
Ambient temperature: 0 to +45 °C
KW-Number: 1100425

Activation of descent prevention ABV2017

Connection examples:

A4-10-Baugruppen-Gerte-Bedienfelder-Schaltschrank1.png

The ABV2017 is sufficient for anti-drop devices with coil voltage 24V DC.

A4-10-Baugruppen-Gerte-Bedienfelder-Schaltschrank2.png

For anti-drop devices with coil voltage 12V DC, the ABV-XP must also be connected.